LCD Inverter 3000-5000


LCD INVERTER 3000 & 5000


ips-3000-front panel
ips-3000-backpanel

ips5000-front panel

ips5000-backpanel












Application








Key Features & Benefits
- 2 types of capacity model available: IPS3000, IPS5000.
- Super efficient DC to AC conversion, minimizing charging losses.
- High frequency technology, provides critical overload protection.
- User selectable for accepting wider input voltage.
- Full automatic start operation and silent operation.
- Compact size for convenient use and storage.
- Small scale and cost effective inverter for home appliances and office equipment.
- Eco-friendly and non-polluting (green device).



Carefully unpack the inverter/charger from its shipping carton.
Verify all of items list below are present. Please call customer service if any items are missing.

A/. The unit
B/. 1 user’s manual

Basic Configuration
The following illustrations show basic applications for IPS3000P 3KVA. They include the following configurations:

1. Utility Backup. see figure 1
2. Renewable Energy Source And a Generator, see figure 2
Consult with your system design for other possible configurations depending on site or code requirements.

FIGURE 1 : UTILITY BACKUP


Figure 2 : Renewable Energi Source
IPS3000P 3KVA Inverter can feeds almost all kinds of appliances from home to office environment,including motor characteristic  appliances like tube light, fan, refrigerator and Air conditioner.

Note: 

Appliances like Air conditioner needs at least 3 minutes to restart in case of a power shortage occurs in a way that the power turns off then back on again rapidly (time is required to balance the refrigerant gas in inside circuit); so in order to protect your Air conditioner, please consult the Air conditioner manufacturer whether they have already provided time delay function before installing. Otherwise, Inverter will trig overload fault and shut off its output to protect your appliance but sometimes it is not enough and your Air conditioner can be damaged internally beyond repair.

Batteries
The unit support 24volt battery bank. Please refer to figure 3 to wiring battery correctly. Before proceeding, ensure you have appropriate size batteries for this inverter. The unit can use flooded lead-acid, or sealed GEL/AGM lead-acid batteries so ensure that your batteries are in one of these categories. The battery must be wired to match the units DC input voltage specifications. Suggest battery capacity not smaller than 100AH.
 
Figure 3: IPS3000P,batteries string wiring

Battery Cable Size
Below table 1 you can find information for recommended battery cable and terminal.


Table 1: information for recomended battery cable and terminal

DC Disconnect and Over-Current Protection
For safety and to comply with regulations, battery over-current protection and disconnect devices are required. Fuses and disconnects must be sized to protect the DC cable size used, and must be rated for DC operation. Do not use devices rated only for AC service – they will not function properly. Note that some installation requirements may not require a disconnect device, although over-current protection is still required.

Battery Cable Connection




















AC Cable Size
Before wiring the input and output of inverter, refer to table 2 for minimum recommended cable size and torque value.
Table 2. Recomended Cable Size and Torge value for AC Wire




AC Connections
Figure 5 : AC Cable Connection to Unit
Installation should be done by a qualified electrician. Consult local code for the proper wire sizes,connectors and conduit requirements. On the left of rear chassis is the AC hardwire cover. Two three-station terminal block is provided to make the AC connections. The terminal block is used to hardwire the AC input, AC output, and ground. The National Electrical Code requires that an external disconnect switch be used in the AC input wiring circuit. The AC breakers in a sub panel will meet this requirement.

Step 1: Disconnect the unit from the battery by removing the battery cables from the battery. Turning off the unit does not constitute disconnecting from the battery.

Step 2: Following the wiring guide located in the AC input wiring compartment as figure 5, connect the GND (green/yellow), Line (brown), and neutral (blue) wires from the AC input (utility, generator, etc) to the terminal block.

Step 3: Connect the AC Line output wiring to the terminal marked AC Line (output), following the wiring guide inside the compartment. Torque the wires into the terminal block.

Step 4: Lock the AC covers.

OPERATION
Front Panel and Configuration Switch


Table 3. Configuration button function

Table 4. Configuration pages option























































    










Note: 
There are 5 configuration pages totally, change only active by enter button pressed within current page.
Indicator & Alarm
Battery capacity segment will lighting to comply with battery voltage.

1. Charger Mode, Battery Indicator
2. Inverter Mode, Battery Indicator







Load indicator:
The load indicate the load percentage comply with load VA or W (show the bigger value), the overload label will flash when overload.














Operating Indicators 

                1. Stanby Mode :                                  2. Inverter Mode :
Voltage & Frequency Exchanged every 5 scnd
      Voltage & Frequency Exchanged every 5 scnd








3. Line Mode :                                                    4. Warning Mode:
Voltage & Frequency Exchanged every 5 second
Red back light flash every 1 second



            5. Saver Mode :                                 6. Fault Mode :
Output Voltage Display Flash every 1 second
Red back light keep On