Jumat, 19 Juni 2015

POWER SERIES/3P-3P/15KVA-120KVA


POWER SERIES/3P-3P/15KVA-120KVA

 POWER SERIES/3P-3P/15KVA-80KVA















The Power Series true on-line double-conversion technology UPS system applied with state-of-the-art PWM technology which can easily adapt to all kinds of diverse and complicated loads, such as the non-linear system, strongly inductive or capacitive loads, discharge lamps, and induction motors. With range from 15kVA to 80kVA, an advanced control with adaptive feed forward cancellation (AFC) technology to achieve extremely low input current harmonic distortion rat THDi < 1% at full load. Applied with DSP controller and the forth generation IGBT transistors, the UPS can achieve high efficiency of up to 95%. The Power Series UPS is a unit with high flexibility in adapting inputs and output and may easily be set up depending on the requirement of the facility. With the space saving compact design, it makes installation and operation easily and eco-environmentally. To facilitate expansion easily, this unit can be set up in parallel redundancy systems without any need for additional hardware in the near future. The Power Series also has a variety of communications and options available.

Key Features and Benefits
- Online double conversion technology with DSP control
- Advanced control with Adaptive Feed Forward Cancellation (AFC) technology for very  

  low harmonic distortion
- Very low input current distortion (THDi < 1%)
- Input power factor 0.99 at 10%load
- Output efficiency up to 95%
- Space-saving compact design
- Front access makes maintenance and replacement easily

- Highly flexibility in single phase / three-phase set-ups
- Control designed to withstand all kinds of loads
- Variety of communication options available
- Over 60%materials recyclable
- Optional N+X parallel redundancy
- Remaining backup time calculation


Applications




Rear Panel (Internal)
For 15kVA to 80kVA model

1. Relay interface
2. Emergency Power Off (EPO)
3. RS-232 COM ports
4. Intelligent Slow
5. Input circuit breaker
6. Maintenance bypass switch
7. Output switch
8. Battery switch
9. System Terminal
10. Parallel port (only available for parallel  model)


For 100kVA to 120kVA model
1. Relay interface
2. Emergency Power Off (EPO)
3. RS-232 COM ports
4. Intelligent Slow
5. Input circuit breaker
6. Maintenance bypass switch
7. Output switch
8. Battery switch
9. System Terminal
10. Parallel port (only available for parallel model)






Full Specifications : 15KVA-80KVA






















Full Specifications : 100KVA-120KVA






















The Most Versatile Solution For Power Protection 
The Power Series is designed with the new state of art transformerless PWM technology that can be easily adapted to any kinds of complicated loads such as the non-linear systems (IT systems), highly inductive/ capacitive loads, high-density discharge lamps and induction motors. The Power series is designed with 2 important criterions in mind; maximum efficiency and energy conservation. The unit also comes with a small form factor to allow for minimum installation effort. Furthermore, a parallel redundant system is integrated to allow two UPS models to operate in parallel as backup for each other. 
The Power Series is available in capacities ranging from 15 to 120kVA.
Online Double Conversion Technology with DSP ControlThe Power Series is able provide a higher load up-time and effective insulation against network disturbance with its online double conversion technology. A Digital Signal Processor (DSP) controller improves the performance and efficiency of the UPS. 

Advanced Control with Adaptive Feed Forward Cancellation (AFC) Technology
By cancelling both the input current and the output voltage harmonics, the harmful effects of harmonic injection can be eliminated and this enhances the load integrity.


Low Input Current Distortion (THDi < 1%)
AFC cells are used to achieve extremely low distortion values. The Power series is able to obtain a low input current distortion at THDi < 1% under full load and a THDi < 5% under smaller load (i.e. 10% of load). This will prevent distortion of electrical network upstream and thus, result in the reduction of cable usage and protective devices in the electrical network.


Input Power Factor 0.99 At 10% Load
Lower power losses would result in reduced consumption, lower operation and maintenance costs.

INPUT POWER FACTOR 0.99 AT 10% LOAD














Output Efficiency of up to 95%
Designed with a DSP controller and fourth generation IGBT transistors, the UPS is able to achieve extremely high efficiency of up to 95%. With such high ratings, components in the UPS are not only protected but also prolonged due to the decrease in heat losses.













Small Form Factor
Utilizes a transformerless technology allows the design of the UPS to be lighter and smaller.


Front Access conceptAn important consideration has been given during the UPS design phase to create a system that allows users to access the unit’s electronic cards and power components with minimum effort. All electronic boards and components can be accessed from the front
panel for easy maintenance and replacement activities.

Versatile Single-Phase / Three-Phase set-ups
This highly versatile UPS is designed with different types
of setting-up options;
Three-phase input / Three-phase output (III/III)
• Three-phase input / Single phase output (III/I)


Control Components are designed to with stand all kinds of loads
In the Power Series, the control components are designed to withstand all types of loads. These include loads such as; resistive, capacitive, non-linear, high-density discharge lamps, induction motors, speed drives etc. This makes the UPS extremely compatible with many types of electronics. Better yet, the UPS comes with a wide array of parameters that can be programmed locally or remotely to fit different types of
environment.
 
Variety Of Communications And Option Available
The UPS has provided the following standard communication selections:
Relay interface
• RS-232/485 port
• 1 × SNMP slot
• Modbus RTU / SEC protocol
• 2 × connectors for parallel connection


Made of 60% Recyclable Materials
When it comes to conserving the environment, PROLiNK is committed to play a part by designing their UPS products using recyclable materials.

Back-up Time indicator
With the use of simple algorithms, an estimated remaining back-up time can be calculated and indications will be reflected on a LCD panel.

5.7” Multiple Languages Graphical LCD Display
Our team of specialists has gathered together to revolutionize the UPS usability by adding in a 5.7” LCD monitor display with all information and alarm notifications viewable within a single display.

N+1 Redundancy
A parallel redundant system allows 4 UPS models to
operate in parallel and as backup for each other




Tidak ada komentar: